Liên hệ
Chúng tôi là nhà phân phối chính thức và duy nhất các sản phẩm của Miki Pulley tại thị trường Việt Nam, Quý khách có nhu cầu về các sản phẩm của Miki Pulley vui lòng liên hệ trực tiếp với chúng tôi để được tư vấn nhanh hơn.
Hotline: 0974190088/Zalo
Email: vuonguoc@gmail.com
BEH Models
BEH Models
[Specifications]
Model | BEH-10G | BEH-20G | BEH-20G-1 | |
---|---|---|---|---|
Input voltage | AC200V ± 10% | AC200V ± 10% | AC100V ± 10% | |
Single phase, 50/60 Hz | ||||
Output voltage | Overexcitation voltage | Initial value 100 V, 0 to 250 V variable | ||
Constant excitation voltage | Initial value 24 V, 0 to 250 V variable | |||
Reverse excitation voltage | Initial value 100 V, 0 to 250 V variable | |||
Voltage control method | PWM control | |||
Output current | 2 A | 4 A | 4 A | |
Applicable clutche/brake size | 06 ~ 16 | 06 ~ 32 | 06 ~ 32 | |
MIKI PULLEY electromagnetic-actuated clutches and brakes Rated voltage DC 24 V | ||||
Protective functions | Undervoltage protection, overvoltage protection, overcurrent protection/detection, break detection, element overheating protection, input-side fuse (20 A) | |||
Usage environment | -10 – +50℃ / 10 – 90%RH | |||
Mass | 0.85kg | 0.9kg | 0.9kg |
[Dimensions]
[Structure]
[Operating Settings]
Operating settings SW (SW3) Switch No. | ON (Up) | OFF (Down) | OFF | |
---|---|---|---|---|
1 | Settings/operating modes | Setup mode | Operation mode | OFF |
2 | Stand-alone/interlocked mode | Stand-alone mode | Interlocked mode | OFF |
3 | Break/overcurrent detection | Enabled | Disabled | OFF |
4 | Current/voltage control | Current control | Voltage control | OFF |
5 | Control AUX | Enabled | Disabled | OFF |
6 | Jog operation | Enabled | Disabled | OFF |
7 | Slope operation | Enabled | Disabled | OFF |
8 | One-shot operation | Enabled | Disabled | OFF |
[Terminals and Functions]
Terminal symbol | Terminal name | Function description |
---|---|---|
R-S | Power supply input terminal | Connector for a commercial power supply |
CL-P | Clutch output terminal | Connector for a clutch |
BR-P | Brake output terminal | Connector for a brake |
Ground | External ground terminal (third class ground or more) | |
1 | Power supply terminal + | Positive terminal of control power supply (shared with the internal supply’s +24 V) |
2 | Power supply terminal – | Negative terminal of control power supply (shared with the internal supply’s 0 V) |
3 | Control AUX | When operating switch 5 (AUX operation) is on, executes the operation of the conditions set in the table. |
4 | Control clutch | Turns output between P and CL on and off. |
5 | Control brake | Turns output between P and BR on and off. |
6・7 | Alarm output 1 | A relay that operates during an alarm stop (relay output) |
8 | Alarm output 2 | Output operates during an alarm stop (transistor output) |
[Characteristics]
Operating response
Noise During Operation
Output Control System
Supply Voltage Fluctuations and Output Voltage
[Wiring methods and timing charts]
Operating mode (Operating Settings SW-2 Off)
Stand-alone operation mode (Operating Settings SW-2 On)
BEH Models, BEH Models, BEH Models, BEH Models, BEH Models, BEH Models BEH Models, BEH Models, BEH Models